Orion Lab Star EC112 conductivity bench meters measure conductivity, salinity or TDS with temperature, feature a large backlit display for easy viewability, and offer small footprint to save bench space. This conductivity meter is ideal for simplified, budget-friendly lab testing and data recording.

Measure conductivity, salinity or total dissolved solids with temperature using the Orion Lab Star EC112 conductivity bench meter. Featuring a large, backlit display for easy viewability and small footprint to save space, this meter is ideal for simplified, budget-friendly lab testing. Use the onscreen stabilizing and ready indicators to help identify when conductivity meter, salinity meter and TDS meter readings are complete. View active calibration logs with date and time, record key measurements using the 500-point data log with date and time, and output all logs to a printer or computer.

Orion Lab Star EC112 Conductivity Meter Features

  • Budget-friendly conductivity meter for simplified conductivity, salinity and TDS testing
  • Display shows conductivity, cell constant, temperature and temperature coefficient simultaneously for accurate data recording
  • Measure 0.00 μS to 500.0 mS conductivity, 0.00 to 80.0 ppt or 0.00 to 42.0 PSU salinity, 0.00 ppm to 500.0 ppt TDS and -5.0 to 105.0 °C or 23.0 to 221.0 °F to ensure comprehensive measurement capabilities
  • Perform one to five point conductivity and TDS calibrations, one point salinity calibrations and one point temperature adjustment calibrations for proficient SOP compliance
  • Large 5 inch backlit display makes viewing and recording measurements easy
  • Small meter footprint saves valuable bench space in your lab
  • Onscreen stabilizing and ready indicators help identify when readings are complete
  • Date and time data stamped data and calibration logs support GLP compliance
  • View active conductivity, salinity, TDS and temperature calibration logs with date and time stamp to ensure accurate, reproducible measurements
  • Use 500-point data log with date and time stamp to record key measurements
  • Output data and calibration logs to a printer or computer for long-term data storage

Meter and Meter Kits

  • LSTAR1120 is the conductivity meter and stand option, which allows you to purchase your conductivity electrode separately
  • LSTAR1125 is the standard conductivity meter kit option, for common conductivity samples in a wide range of 1 μS/cm to 20 mS/cm
TRUSTED_SUSTAINABILITY

Specifica

Descrizione Orion Lab Star EC112 conductivity/salinity/TDS bench meter with stand
Include Meter with electrode stand, PC cable, universal power adapter
Precisione (conduttività) ±0.5 % of the reading ± 1 LSD
Uscite Computer or printer (STARA-106)
Da utilizzare con (applicazione) Meter and Stand Option, Select and Purchase The Electrode Separately
Measurement Modes Conductivity with Temperature, Salinity with Temperature, TDS with Temperature
Sonde compatibili 2-cell and 4-cell conductivity electrodes
Costante di cella 0.100 to 10.00 cm-1
Calibrazione Conductivity, salinity, TDS and temperature
Punti di calibrazione (conduttività) 1-5 points conductivity
Punti di calibrazione 1 point salinity, 1-5 points TDS, 1 point temperature
Intervallo (conduttività) 0.00 μS to 500.0 mS
Risoluzione (conduttività) 0.01, 0.1, 1 μS; 0.01, 0.1 mS
Compensazione della temperatura Linear (0 to 10 %/°C) or off
Coefficiente di temperatura 0 to 10 %/°C
Temperatura (sistema metrico) di riferimento 15.0, 20.0, 25.0 or 30.0°C
Intervallo (salinità) 0.00 to 80.0 ppt; 0.00 to 42.0 PSU
Risoluzione (salinità) 0.01, 0.1 ppt; 0.01, 0.1 PSU
Precisione (Salinità) ±0.5 % of the reading ± 1 LSD
Modalità di misurazione della salinità Natural Seawater (ppt) or Practical Salinity (PSU)
Risoluzione (TDS) 0.01, 0.1, 1 ppm; 0.01, 0.1 ppt
Precisione (TDS) ±0.5 % of the reading ± 1 LSD
Intervallo fattore TDS 0.40 to 1.00
Temperature Range (Metric) -5.0°C to +105.0°C
Intervallo di temperatura (sistema imperiale) 23.0°F to 221.0°F
Risoluzione (temperatura) 0.1°C, 0.1°F
Precisione (Temperatura) ±0.3°C, ±0.5°F
Selezione della temperatura Manual or automatic with ATC temperature probe
Calibrazione della sonda di temperatura 1 point temperature offset calibration
Tipo di display 5 in. backlit LCD
Opzione di retroilluminazione Yes
Memoria Non-volatile
Punti dati 500 Sets with Date and Time Stamp
Tipo di funzione registro Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode
Dettagli di gestione dei dati Continuous, Auto-Read and Timed read modes
Uscita allarme Calibration reminder alarm
Ingressi 8-pin MiniDIN for conductivity with built-in ATC
Certificazione/Conformità CE, TUV 3-1, FCC Class A
Protezione IP IP54
Adattatore CA Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets
Dimensioni (L x P x A) 187.2 x 155.2 x 61.7 mm, 7.37 x 6.11 x 2.43 in.
Peso (sistema metrico) 700 grams
Peso (sistema imperiale) 1.54 lb.
Warranty 3 year meter warranty
Tipo Conductivity Meter
Vedi altri risultati Mostra meno risultati
Correzione del contenuto del prodotto

Fornite il vostro feedback sul contenuto del prodotto compilando il modulo sottostante.

Titolo del prodotto

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.

Grazie per averci aiutato a migliorare il nostro sito web. Il vostro feedback è stato inviato