Thermo Scientific™ Orion Lab Star EC112 Conductivity Bench Meters

Orion Lab Star EC112 conductivity bench meters measure conductivity, salinity or TDS with temperature, feature a large backlit display for easy viewability, and offer small footprint to save bench space. This conductivity meter is ideal for simplified, budget-friendly lab testing and data recording.

Overview
835.73 GBP valid until 2025-06-30
Use promo code "24108" to get your promotional price.



Additional Details:
Additional Details: Weight: 5.00000kg



Product Code. 17701859

Quantity Price
1 £ 835.73 / Each
In stock, ready to ship: 3
Add to basket


  • Description and Specification
  • Accessories and Spare Parts
  • Special Offers
Description and Specification

Specification

Description Orion Lab Star EC112 conductivity/salinity/TDS bench meter standard kit
Includes 011050MD 2-cell K = 1.0 epoxy-body conductivity/ATC probe; 011007 1413 μS conductivity standard 5 x 60 mL; meter with electrode stand, PC cable, universal power adapter
Accuracy (Conductivity) ±0.5 % of the reading ± 1 LSD
Outputs Computer or printer (STARA-106)
For Use With (Application) For a Wide Variety of Conductivity Samples in The 1 μS/cm to 20 mS/cm Range
Measurement Modes Conductivity with Temperature,Salinity with Temperature,TDS with Temperature
Measurement Modes Conductivity with Temperature,Salinity with Temperature,TDS with Temperature
Measurement Modes Conductivity with Temperature,Salinity with Temperature,TDS with Temperature
Compatible Probes 2-cell and 4-cell conductivity electrodes
Cell Constant 0.100 to 10.00 cm-1
Calibration Conductivity, salinity, TDS and temperature
Calibration Points (Conductivity) 1-5 points conductivity
Calibration Points 1 point salinity, 1-5 points TDS, 1 point temperature
Range (Conductivity) 0.00 μS to 500.0 mS
Resolution (Conductivity) 0.01, 0.1, 1 μS; 0.01, 0.1 mS
Temperature Compensation Linear (0 to 10 %/°C) or off
Temperature Coefficient 0 to 10 %/°C
Temperature (Metric) Reference 15.0, 20.0, 25.0 or 30.0°C
Range (Salinity) 0.00 to 80.0 ppt; 0.00 to 42.0 PSU
Resolution (Salinity) 0.01, 0.1 ppt; 0.01, 0.1 PSU
Accuracy (Salinity) ±0.5 % of the reading ± 1 LSD
Salinity Measurement Modes Natural Seawater (ppt) or Practical Salinity (PSU)
Resolution (TDS) 0.01, 0.1, 1 ppm; 0.01, 0.1 ppt
Accuracy (TDS) ±0.5 % of the reading ± 1 LSD
TDS Factor Range 0.40 to 1.00
Temperature Range (Metric) -5.0°C to +105.0°C
Temperature Range (English) 23.0°F to 221.0°F
Resolution (Temperature) 0.1°C, 0.1°F
Accuracy (Temperature) ±0.3°C, ±0.5°F
Temperature Selection Manual or automatic with ATC temperature probe
Temperature Probe Calibration 1 point temperature offset calibration
Display Type 5 in. backlit LCD
Backlight Option Yes
Memory Non-volatile
Data Points 500 Sets with Date and Time Stamp
Log Function Type Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode
Data Management Details Continuous, Auto-Read and Timed read modes
Alarm Output Calibration reminder alarm
Inputs 8-pin MiniDIN for conductivity with built-in ATC
Certifications/Compliance CE, TUV 3-1, FCC Class A
IP Rating IP54
AC Adapter Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets
Dimensions (L x W x H) 187.2 x 155.2 x 61.7 mm, 7.37 x 6.11 x 2.43 in.
Weight (Metric) 700 grams
Weight (English) 1.54 lb.
Warranty 3 year meter warranty
Type Conductivity Meter Kit

Orion Lab Star EC112 Conductivity Meter Features

  • Budget-friendly conductivity meter for simplified conductivity, salinity and TDS testing
  • Display shows conductivity, cell constant, temperature and temperature coefficient simultaneously for accurate data recording
  • Measure 0.00 μS to 500.0 mS conductivity, 0.00 to 80.0 ppt or 0.00 to 42.0 PSU salinity, 0.00 ppm to 500.0 ppt TDS and -5.0 to 105.0 °C or 23.0 to 221.0 °F to ensure comprehensive measurement capabilities
  • Perform one to five point conductivity and TDS calibrations, one point salinity calibrations and one point temperature adjustment calibrations for proficient SOP compliance
  • Large 5 inch backlit display makes viewing and recording measurements easy
  • Small meter footprint saves valuable bench space in your lab
  • Onscreen stabilizing and ready indicators help identify when readings are complete
  • Date and time data stamped data and calibration logs support GLP compliance
  • View active conductivity, salinity, TDS and temperature calibration logs with date and time stamp to ensure accurate, reproducible measurements
  • Use 500-point data log with date and time stamp to record key measurements
  • Output data and calibration logs to a printer or computer for long-term data storage

Meter and Meter Kits

  • LSTAR1120 is the conductivity meter and stand option, which allows you to purchase your conductivity electrode separately
  • LSTAR1125 is the standard conductivity meter kit option, for common conductivity samples in a wide range of 1 μS/cm to 20 mS/cm

Accessories and Spare Parts
Special Offers